Checklist - Soft Close - Side damper Soft Close, mounted on the upper door rail Pin mounted in the top track Damper with spring X 06/2015 X If the Soft Close damping system is not working properly, please walk through the checklist below. If the problems aren’t solved after that please contact Noteborn Service (mail: service@noteborn.nl or tel. +31 - 45 - 535.77.77). Step 1 • Control the distance between the floor and ceiling and check if this is corresponding with the one on the order confirmation. Step 2 Check if the Soft Close damper is mounted properly on the upper rail. • The damper has to be positioned against the top wheel and should not be able to move. • The part with the spring has to be on the front side of the sliding door. Step 3 Check if the damper and spring function properly. • Pull (you should feel resistance) and release (this should run smoothly) the spring manually. Step 4 Place the door in the upper rail. • Make sure to put the spring under tension before placing the doors in the top track (carrier position open) Step 5 Check the pin in the top track. • Is the pin height correct? Determine the length Z of the pin and cut or saw the pin to the right height. Y = the distance between upper rail and top track after putting the door to the correct height. Y minimal = 33mm bottom upper rail 1,5 Z Z = Y - 18 Y 16,5 top door Cut
Download PDF fil