Versie: 06/2015 Checklist - Soft Close - Middle damper Soft Close, mounted on the upper door rail If the Soft Close damping system is not working properly, please walk through the checklist below. If the problems aren’t solved after that please contact Noteborn Service (mail: service@noteborn.nl or tel. +31 - 45 - 535.77.77). Damper with spring Pins mounted in the top track Step 1 • Control the distance between the floor and ceiling and check if this is corresponding with the one on the order confirmation. Step 2 Check if the Soft Close damper is mounted properly on the upper rail. • The damper has to be positioned in the middle of the door and should not be able to move. • The part with the spring has to be on the front side of the sliding door. Step 3 Check if the damper and spring function properly. • Pull (you should feel resistance) and release (this should run smoothly) the spring manually. Step 4 Place the door in the upper rail. • Make sure to put the spring under tension before placing the doors in the top track. Step 5 Check the pins in the top track • Do the pins have the correct height? Determine the length Z of the pins and cut or saw the them to the right height if necessary. Y = the distance between upper rail and top track after putting the door to the correct height. Y minimal = 36mm bottom upper rail 1,5 Z Z = Y - 18 Y 16,5 top door Cut